Search      Advanced Search

Providing of Potential Transformers (PT) & Current Transformers (CT), Power Resistor, Resistor Current Limiting, Surge Arrester, Surge Protection Capacitor, NGT : .

Request For Proposals

General Information

Country:   Iraq
City/Locality:   Basrah
Notice/Contract Number:   ept:4752533
Publication Date:   Jul 28, 2010
Deadline:   Aug 22, 2010
Buyer:   Ministry Of Electricity
Original Language:   English

Contact Information

Address:   Ministry Of Electricity
General directorate of electrical energy production, Khor Al-Zubair, Power Station
Basrah
Iraq
Email:   Click here

Goods, Works and Services

 

Original Text

     view in:

Opening date of tender: 08/22/2010 00:00

Note: 1) PT - Potential transformer- CL 05/3 P V.T. TO. earthed, Ratio 10500/ v3:110/v3:110/3 PH1, VA 30-20, S. No. IT 03-80, H.S.V. 12000UN IL 35/75 KV, 50 HZ/ IS 3156 / IEC 44.2, V.F 1.2 CONT.1.9/30 SECs, 2) Potential transformer- CL 0.2 – 0.5 Ratio 10500/v3:110/v3:110/v3 PH1 VA 60 - 20 S. No. IT 03-80 H.S.V. 12000UN IL 35/75 KV 50 HZ/ IS 3156 / IEC 44.2 V.F 1.2 CONT.1.9/30 SECs, 3) NGT- Type: NGT SR. No. 02/126731 Pr. Voltage 10.5 KV, Sec. Voltage 200 V Out Put : 10KVA CONT / 60 KVA, Rated Secondary current : 50 A, HSV: 12 KV/ insulation class : B, Impedance : 5%/ Regulation : 5%, Phase 1 service: indoor, 4) CT- CL 5P15, Ratio 300/5, F: 50 HZ, 20 VA, Insulation level 3 KV, ITH / sec 10KA/3 HSV 660 UN, SR. No. 0570, 2-1- CT- CL 5P15, Ratio 300/5, F: 50 HZ, 20 VA, Insulation level 3 KV, ITH / sec- 10KA/3, HSV -660 UN, SR. No. 0570, 2-2) CT- CL 0.5 Ratio10000/5 A. S. No. IT 03-66- freq. 50 HZ -30 VA, Insulation level 35/75 KV H.S.V12000 UN, I.T.H / sec 80 KA/3, IS 2705/ IEC 44.1, ISF > 5, 2-3) CT- CL 0.2 Ratio 10000/5 A S. No. IT 03-66 freq. 50 HZ 30 VA, Insulation level 35/75 KV H.S.V 12000 UN, I.T.H / sec 80 KA/3, IS 2705/ IEC 44.1 ISF > 5, 2-4) CT- CL PS S. No.03-54, Ratio 10000/5, R sec. At 75° C < 2.0 ohm VKP>1000V IM at 500V<50 M, I.T.H 80 KA / 5 sec, I>L 35/75 KV, IS2705/IEC 44.4, 3-1) Power Resistor - Type : coil wound / punched, Rated voltage 200 V, Rated current 250 A, Total resistor 0.7 ± 10% Metal of element S.T. Steel fechard, Duty cycle 5 min per hr, 3-2) Resistor current limiting- MAX w: 100 CONT Resistance: 65 ohm ±5%, SL.No. KSI/ IIB/ 08-02, 4) Surge Arrester- Station Zinc Oxide surge Arrester, Nominal discharge current 10KA Model 5L 123 N H012, Rating 32 KV SER. No. 352, 5) Surge protection capacitor - Model No. 62/13/185, Rating voltage 18 KV, Rating current 1.41 A 50 HZ Capacitance 0.25 micro F, Insulation level 35/75 KV, Type of impermanent MPCB Discharge device international RES.
Please note that this notice is for your information only.
We try our best to have the most accurate and up-to-date information available on our web site, but we cannot guarantee that all of the information provided is error-free.
If you have any suggestions for updates/corrections for this notice, please let us know.