(i) This is combined synopsis/solicitation for commercial items number F2QT326156A100 issued on June 19, 2006 for commercial items prepared in accordance with the format in the Federal Acquisition Regulation (FAR) Subpart 12.6, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation proposals are being requested and a written solicitation will not be issued. The solicitation will be issued on the World Wide Web and can be found at the following web site: http://www.eps.gov/. (ii) Solicitation F2QT326156A100 is issued as a Request for Quote using Simplified Acquisition Procedures under the test program for certain commercial items found at FAR Part 13.5. (iii) The solicitation document and FAR incorporated provisions and clauses are those in effect through Federal Acquisition Circular (FAC) 2005-09 and Defense Federal Acquisition Regulation Supplement, Defense Change Notice (DCN) 20060519. Special Provisions and the Representations, Certifications and Other Statements of Offerors or Quoters are included with this solicitation as an attachment. (iv) This acquisition is a 100 Small Business Set-Aside IAW FAR 19.502-2(b). The NAICS code is 334515 and the small business size standard is 500 employees (v) The 1st Contracting Squadron has a requirement for a RF Spectrum Analyzer for JTIDS/MIDS. The requirment for the RF Spectrum Analyzer will be: N1996a C Agilent CSA Spectrum Analyzer Qty 1 N1996A-P03 C Preamplifier, 3GHZ, Qty 1 N1996A-TG3 C Tracking Generator, 3GHZ, Qty 1 N1996A-271 C Spectrogram Measurment, Qty 1 N8995A-1FP C Stimulus Response Measurement Suite, Qty 1 N1996A-BAT C Battery Pack, Qty 1 N1996A-SRK C Stimulus Response Calibration Kit, Qty 1 N1996A-ABA C English Printed Measurement Guide, Qty 1 Place of delivery for acceptance and FOB point will Bldg 25 37 Elm St Loading Dock A, Langley AFB, VA 23665. (viii) The following FAR provisions and clauses are applicable to this procurement: 52.212-1, Instructions to Offerors--Commercial Items (JAN 2006), (ix) Solicitation provision at FAR 52.212-2, Evaluation C Commercial Items (JAN 1999), (a) The Government will award a purchase order resulting from this solicitation to the responsible offeror whose offer conforming to the solicitation will be most advantageous to the Government. (x) Offerors are reminded to include a completed copy of the Representations, Certifications with his/her offer. (xi) Wherever the word Government is used NAFI is substituted in lieu thereof. (xiii) N/A (xiv) The Defense Priorities and Allocation Systems (DPAS) assigned rating for this procurement is unrated. (xv) There are no numbered notes applicable. (xvi) This announcement will close and quotes are due by 2:00 PM (EST) 1 July 2006. Signed and dated offers, to include a complete listing of all items, must be submitted to 1st Contracting Squadron/LGCB, Attn: Robert Lieder III, 74 Nealy Avenue, Suite 100, Langley AFB, VA 23665-2088. Responsible sources may submit a bid, proposal, or quote which shall be considered. Offers may be submitted via mail, email or facsimile. (xvii) POC: Robert Lieder III at 757-764-5802, fax 757-764-7447, or e-mail robert.lieder@langley.af.mil.
Requirements for RF Spectrum Analyzer
Frequency
Range 100 kHz to 3 GHz (Option 503)
Frequency reading accuracy frequency indication x frequency reference accuracy 1 x span 10 x RBW 0.5 x span/(sweep points -1) 1Hz
Internal reference accuracy 5 ppm/year (within 2 years of adjustment)
Aging rate 2 ppm/year
Temperature stability 1 ppm
Resolution bandwidth (RBW) 10 Hz to 200 kHz in 1 steps, 250 kHz, 300 kHz, 1 MHz, 3 MHz, 5 MHz
Selectivity (60 dB/3 dB bandwidth ratio) Digital, approximately Gaussian shape
0 RBW 200 kHz < 8.4:1 (nominal)
0 RBW 250 kHz < 4.5:1 (nominal)
Zero span RBW 10 kHz < 6.5:1 (nominal)
Zero span RBW 200 kHz < 3:1 (nominal)
Accuracy
0 (nominal)
0 (nominal)
Phase noise -85 dBc at 10 kHz offset (500 MHz to 2.5 GHz, typical)
-124 dBc at 1 MHz offset (10 to 2.2 GHz, nominal)
Sweep and trace update times
Sweep time setting range (zero span) 2 s to 10 s
Local trace update
Span 100 MHz 3 updates/sec maximum
Span 1 GHz 1 update/sec maximum
Remote sweep and trace transfer
Span 0 120 ms minimum
Span 100 MHz 180 ms
Span 3 GHz 1 sec
Amplitude accuracy (20 to 30 C)
Overall amp accuracy (95)
(20 to 30 C, peak detector, preamplifier off, 0.5 dB 10 MHz to 1 GHz
input signal 0 dBm to -50 dBm) 0.6 dB 1 GHz to 3 GHz
0.8 dB 3 GHz to 6 GHz
Absolute amp accuracy at 50 MHz ref 0.4 dB
Frequency response 0.7 dB 250 kHz to 10 MHz
(when RBW 200 kHz) 0.4 dB 10 MHz to 1 GHz
0.6 dB 1 GHz to 2.7 GHz
0.7 dB 2.7 GHz to 3 GHz
1.1 dB 3 GHz to 6 GHz
Scale fidelity 0.2 dB (-10 to -80 dBm mixer level)
RBW switching 0.3 dB
Attenuator switching 0.2 dB (nominal)
Amplitude
Maximum average continuous power 33 dBm
Maximum DC 50 V dc
Input attenuator range 0 to 40 dB in 1 dB step
Preamplifier 100 kHz to 3 GHz
Gain 22 dB (nominal) < 2.7 GHz
18 dB (nominal) < 6 GHz
Tracking generator and internal bridge 10 MHz to 3 or 6 GHz (Option TG3 or TG6)
General
Internal data storage 2 MB for user states and traces
Display 21.3 cm (8.4 inches), color, XGA TFT-LCD
Weight with batteries 8.5 kg
Weight without batteries 7.5 kg
Dimensions without bumpers and handles 17.7 x 42.5 x 23.2 cm
Operating temperature A/C power: 0 to 40 C battery power: 0 to 50 C
Probe power output 15 V at 150 mA
-12 V at 150 mA
EMI compatibility
Radiated emissions CISPR 11, Class A
Conducted emissions CISPR 11, Class A
Input/output
RF input Type N, female (50 )
Tracking generator output Type N, female (50 )
USB-A USB 1.1 (low power device only)
LAN 10/100 Base-T RJ-45 connector
Reference out BNC (female), 10 MHz, 0 dBm nominal
Reference in BNC (female), 1 MHz, 2.048 MHz, 4.95 MHz, 10 MHz, 13 MHz, 15 MHz, 19.6608 MHz, 0.5 Hz (even second clock), -5 to 10 dBm nominal
External trigger input BNC (female)

Set-aside code: Total Small Business
Place of performance:
 74 Nealy AveLangley AFB
 23665
 USA
Contact: Robert Lieder, Contract Administrator, Phone 757-764-5802, Fax 757-764-7447, Email robert.lieder@langley.af.mil - Michele Burk, Contract Administrator, Phone 757-764-8619, Fax 757-764-7447, Email michele.burk@langley.af.mil

Link to FedBizOpps document.


Updated on 2006/06/19

Please note that this notice is for your information only.
We try our best to have the most accurate and up-to-date information available on our web site, but we cannot guarantee that all of the information provided is error-free.
If you have any suggestions for updates/corrections for this notice, please let us know.